WONDER — The Mystery
Pressure Can Trade with Speed and Height
Along a steady ideal streamline, greater speed at the same height corresponds to lower static pressure. What changes if the fluid also descends? Why can a fast jet have atmospheric static pressure rather than automatically lower pressure than all nearby slow air?
Model: Steady incompressible inviscid flow along one streamline, with no pump/turbine work or dissipative loss between compared points. Bernoulli conserves pressure plus kinetic and gravitational energy per volume. Use a common pressure reference and a common elevation datum. Comparing unrelated flows needs additional information; faster fluid does not universally mean lower static pressure.
PREDICT — Commit to Your Answer
DOK 2 — PredictA steady incompressible inviscid flow narrows along the same horizontal streamline. There is no pump, turbine or loss between the sections. The narrow section has higher speed. How does its static pressure compare?
Commit to both a prediction and a reason before revealing the explanation.
Step 1: Pick your answer.
STOP! Before revealing — why did you pick that?
Correct prediction and reasoning saved.
P1 + ½ρv1² = P2 + ½ρv2² under these conditions. Greater v2 makes P2 smaller. A height change or added energy can alter the comparison.
▶ PLAY — Live Parcel with Pressure, Speed and Height Accounting
DOK 2 — InvestigatePredict, measure and compare
Compare two outlet areas at fixed flow and elevation change. Then change only outlet elevation from one of that pair. Complete three runs. Follow the gold parcel while its local pressure, speed and elevation change; verify the same Bernoulli sum.
A filled ideal pipe has A1 = 0.0040 m² and selected A2. Uniform density is 1000 kg/m³, g = 9.8 m/s² and inlet absolute static pressure is 120 kPa. Ambient reference is 100 kPa. Q is externally regulated, with no source or loss between inlet and outlet. Horizontal inlet and outlet lengths are 0.80 m each. The transition has horizontal span 0.40 m and elevation change Δy, so its actual length is √(0.40² + Δy²). Area changes linearly with distance along that segment. Local speed is Q/A, and parcel position follows the cumulative volume coordinate. Pressure follows the same energy constant. All allowed absolute pressures remain positive. Diagram length and width are schematic; one physical parcel transit plays over 8 real seconds.
Status: Ready
Playback: 8 real seconds per run; read elapsed physical model time. Pause or Step for measurements.
Measurements
Load givens — then predict and run
Loading a setup earns no trial credit.
♢ DISCOVER — Energy Terms and Valid Comparisons
DOK 1 — RecallFlip all 4 rule cards. Keep the quantities and model conditions clear.
Rule 1
The Bernoulli sum
Click to flip
The Bernoulli sum
P + ½ρv² + ρgy is constant along a steady incompressible inviscid streamline without added work or losses. Each term has units Pa = J/m³.
Rule 2
Keep height and signs
Click to flip
Keep height and signs
P2 = P1 + ½ρ(v1² − v2²) + ρg(y1 − y2). Higher speed or higher elevation can reduce pressure. A descent can raise pressure while speed also increases.
Rule 3
Continuity supplies geometry
Click to flip
Continuity supplies geometry
For uniform-density steady flow, A1v1 = A2v2. Circular area scales with radius or diameter squared. Do not prescribe inconsistent speeds and areas in a filled pipe.
Rule 4
Static pressure is not impact pressure
Click to flip
Static pressure is not impact pressure
The kinetic term is dynamic pressure, not the fluid’s static pressure. A stagnation measurement stops flow along a suitable streamline and relates the two. Unrelated flows, jet mixing and real wing pressure fields need their own conditions.
All rules explored.
MISCONCEPTION ATTACK — Destroy the Myths
DOK 2 — AnalyzeChoose TRUE or FALSE for each claim. The explanation appears after an attempt; only a correct answer completes the claim.
Myth 1: “Every faster fluid everywhere must have lower static pressure than every slower fluid.”
Correct — the claim is false.
False. The same Bernoulli constant and valid streamline conditions are needed. A free jet can have nearly ambient static pressure, while unrelated streams can have different energy constants.
Myth 2: “Doubling speed makes the pressure drop equal to four times the original kinetic term.”
Correct — the claim is false.
False at equal height. The final kinetic term is four times the original, but its increase is three times the original. Pressure drops by the increase, with any height and work terms also accounted for.
Both myths corrected. Continue to the instructor questions.
✦ THE SECOND “AHA!” — Energy Changes with Conditions
DOK 2 — ApplyUse a consistent datum and calculate changes rather than confusing final terms with differences.
Instructor Q1 — The Scope
Where is the simple Bernoulli sum conserved under this mission’s model?
Instructor Q2 — Doubling Speed
At equal height, v doubles in a valid ideal comparison. How does the kinetic term ½ρv² change?
Instructor Q3 — Fresh Horizontal Pressure
Along a horizontal ideal water streamline, absolute P1 = 140 kPa, v1 = 1 m/s, v2 = 5 m/s and density = 1000 kg/m³. Find absolute P2 in kPa.
Instructor Q4 — Equal Speeds, Higher Outlet
Along an ideal liquid streamline speeds are equal and the outlet is 0.50 m higher. Inlet gauge pressure is 70 kPa, density is 1000 kg/m³ and g = 10 m/s². Find outlet gauge pressure in kPa using the same ambient reference.
4/4 — Instructor Questions Completed
At equal height along a valid ideal streamline, increasing speed lowers static pressure. Keep the full equation when height or energy conditions change.
✎ PRACTICE — Independent Streamline Energy Cases
DOK 1–3 — PracticeChallenge 1: A Horizontal Ideal Flow
A steady incompressible inviscid liquid follows a horizontal streamline with no added work or losses. Density is 900 kg/m³. At point 1 absolute pressure is 150 kPa and speed is 2.0 m/s; point-2 speed is 6.0 m/s. Find absolute point-2 pressure and the pressure drop, both in kPa.
Step-by-Step Solution
Kinetic-term increase = ½(900)(6.0² − 2.0²) = 14400 Pa = 14.4 kPa. Absolute P2 = 150 − 14.4 = 135.6 kPa.
Challenge 2: A Narrower, Higher Section
A filled ideal pipe carries steady water of density 1000 kg/m³; g = 10 m/s². Inlet area is 0.0060 m², outlet area 0.0030 m², inlet speed 1.20 m/s and inlet gauge pressure 80.0 kPa. The outlet is 1.50 m higher. Both points use ambient pressure 100 kPa as their gauge reference. With no added work or losses, find outlet speed, outlet gauge pressure and outlet absolute pressure.
Step-by-Step Solution
Outlet speed = (0.0060/0.0030)(1.20) = 2.40 m/s. Gauge P2 = 80000 + ½(1000)(1.20² − 2.40²) − 1000(10)(1.50) = 62840 Pa = 62.84 kPa. Absolute P2 = 162.84 kPa. Common ambient pressure cancels from the energy difference.
Challenge 3: Audit the Fast-Flow Slogan
A steady incompressible inviscid liquid of density 1000 kg/m³ follows one streamline without added work or losses. Point-1 absolute pressure is 130 kPa and speed is 3.0 m/s. Point 2 is 1.00 m lower with speed 6.0 m/s; g = 10 m/s². A report uses the final kinetic term as the pressure drop rather than its increase, ignores the descent, and extends its result to every unrelated fast fluid. Find the kinetic-term increase, signed change in gravity term from point 1 to 2, and point-2 absolute pressure, all in kPa-equivalent units. Explain all three errors.
Step-by-Step Solution
K1 = 4.50 kPa and K2 = 18.0 kPa, so kinetic increase is 13.5 kPa, not 18.0 kPa. Taking y1 = 0 gives y2 = −1.00 m, so gravity-term change is −10.0 kPa. Pressure change is −13.5 − (−10.0) = −3.50 kPa; P2 = 126.5 kPa.
The descent supplies part of the kinetic increase. Ignoring it overstates the pressure drop. Bernoulli relates points along the stated valid streamline; unrelated flows may have different energy constants, so a universal speed-pressure slogan does not follow.
☷ CHALLENGE — Sort the Energy Terms and Conditions
DOK 2 — ApplySort the Energy Terms and Conditions
Identify whether the statement concerns static pressure, kinetic energy or the remaining conditions.
0 / 6 correct
Physics Insight
All three terms have Pa-equivalent units, but they describe different physical contributions.
TEACH — The Feynman Technique
DOK 3 — TeachYour Final Mission: Explain Bernoulli’s energy balance along a valid ideal streamline. Show why greater speed lowers static pressure at equal height, explain how a descent can offset that drop, and distinguish static pressure from the kinetic term without making a universal speed-pressure claim.
Use simple words and at least three short sentences. This checks effort; compare your physics with the Vault or your teacher.
Type Your Explanation (≥ 3 sentences)
Draw a labelled explanation with at least three purposeful strokes. This checks effort; compare your physics with the Vault or your teacher.
Cyan pen selected.
Final reward below
Hidden exam secrets inside — Crest's private notebook.
Crest’s Secret Notebook
Mission 7.10 — Bernoulli’s Principle
Balance pressure, speed and height along a valid streamline.
1. Bernoulli’s equation and assumptions
P + ½ρv² + ρgy = constant along the stated streamline
Use steady incompressible inviscid flow and no pump/turbine work or loss between the points. Every term has units J/m³ = Pa. P is static pressure; the kinetic and gravitational terms are energy per volume. The same constant need not apply to unrelated streamlines or separate flows.
2. Correct changes and height sign
P2 − P1 = −½ρ(v2² − v1²) − ρg(y2 − y1)
At equal height, increasing speed lowers static pressure. A higher outlet consumes gravitational energy per volume; a lower outlet releases it. Increasing speed does not necessarily lower pressure if a descent or added work offsets the kinetic increase.
If speed doubles, final kinetic term is 4Kinitial, but the increase is 3Kinitial. Pressure responds to the increase with other terms included. In the audit, kinetic increase is 13.5 kPa and gravity change −10.0 kPa, giving P2 = 126.5 kPa.
3. Pressure references
Absolute pressure is measured from vacuum. Gauge pressure subtracts an ambient reference. Use one common reference on both sides; subtracting the same reference preserves the Bernoulli pressure difference. Do not mix one absolute and one gauge number directly.
The horizontal practice gives 135.6 kPa absolute. The raised-outlet practice gives speed 2.40 m/s, gauge pressure 62.84 kPa and absolute pressure 162.84 kPa with ambient 100 kPa.
4. Continuity and energy are distinct
For steady constant-density filled flow, A1v1 = A2v2 links areas and speeds. Bernoulli adds the energy/pressure relation. Prescribing incompatible areas and independent speeds would violate continuity. A source’s required work must be included if a pump lies between compared points.
5. Static, dynamic and stagnation pressure
The kinetic term ½ρv² is often called dynamic pressure. It is not identical to static pressure. Suitable ideal stagnation slowing at equal height gives stagnation pressure = static pressure + dynamic pressure. A jet at a free boundary can have ambient static pressure despite high speed. Impact forces involve momentum change and the full flow conditions.
A real wing’s lift comes from its pressure distribution and momentum deflection. A supplied uniform pressure difference over a flat effective area can use F = ΔPA; general lift requires integrating the pressure distribution. Air parcels do not have an equal-transit-time requirement. Spin, jet entrainment, curtains and buoyant chimney flows should not be reduced to one universal Bernoulli slogan.
6. Faithful live parcel model
Area changes linearly along the actual sloping transition length √(0.40² + Δy²). The parcel’s cumulative volume coordinate advances by Qt, giving local speed Q/A. Its elevation follows the same pipe segment. Local P is then the conserved energy sum minus kinetic and gravity terms.
Density is 1000 kg/m³, g = 9.8 m/s², inlet absolute P is 120 kPa and ambient is 100 kPa. Every permitted setting keeps absolute pressure positive. The pipe drawing is schematic; real parcel travel time depends on pipe volume/Q and is played over 8 real seconds.
The source holds Q fixed outside the inlet-to-outlet comparison. There are no pumps or losses between those points. Compare outlet areas, then outlet heights, keeping other settings fixed. Moving parcels and every displayed energy term share the same physical state.
7. Course scope
Bernoulli and ideal-fluid conservation directly support AP Physics 1 topic 8.4. They are extension material beyond named Cambridge AS Level 9702 fluid content. Apply the assumptions explicitly; real viscous or compressible flows may need different equations.
✓ Crest’s Checklist
- I state Bernoulli’s streamline and ideal-flow conditions.
- I keep pressure references consistent.
- I use one elevation datum and signed differences.
- I subtract initial from final kinetic terms.
- I apply continuity consistently with geometry.
- I distinguish static and dynamic pressure.
- I avoid universal claims about unrelated flows.
— Crest ☆ “Balance pressure, speed and height along a valid streamline.”
Mission 7.10 Complete! · All 10 levels cleared · PHYSICS CREST
★ Bernoulli Principle Master
At equal height along a valid ideal streamline, increasing speed lowers static pressure. Keep the full equation when height or energy conditions change.