WONDER — The Mystery
Each Wire Acts on the Other
Two long parallel wires carrying currents can attract or repel. Each produces a tangential magnetic field at the other; that field then acts on the other current. Different current magnitudes do not make the reciprocal forces unequal on equal interacting lengths.
Model: For ideal long straight parallel wires in vacuum, magnitude F/L = μ₀|I₁I₂|/(2πd). Same-direction currents attract; opposite-direction currents repel. d is the perpendicular axis separation. The field at a wire is due to the other source, not its own field in this interaction calculation.
PREDICT — Commit to Your Answer
DOK 2 — PredictTwo long parallel wires carry currents of 3 A and 9 A in the same direction. Compare the magnetic forces on equal interacting lengths.
Commit to both a prediction and a reason before revealing the explanation.
Step 1: Pick your answer.
STOP! Before revealing — why did you pick that?
Correct prediction and reasoning saved.
Both magnitudes are μ₀|I₁I₂|L/(2πd). They are equal and opposite for the ideal parallel geometry; same-direction currents attract.
▶ PLAY — Two Wires Actually Move Together or Apart
DOK 2 — InvestigatePredict, measure and compare
Compare two values of I₁ while holding I₂ and initial spacing fixed, then two initial spacings with currents fixed. Watch both wires translate as their instantaneous separation and mutual force change. Check reversed I₂ and zero current.
Two effectively long parallel nonmagnetic wires have equal mass per unit length μ = 0.020 kg/m and regulated steady currents. I₁ is positive out of the page; signed I₂ is positive out, negative into the page. Their cross-sections move symmetrically along x from rest; the center stays fixed. Initially separated by d₀, they obey d″ = −2k/(μd), where k = 2×10⁻⁷ I₁I₂ in SI units. Each force per length has magnitude |k|/d, so force changes during motion. A numerical velocity-Verlet integration uses 0.001 s steps. Protective supports stop inward motion at d = 0.030 m and remove kinetic energy at contact; no singular collision is modeled. The wires remain parallel; gravity and lead forces are supported and end effects neglected. Regulated sources supply or absorb electrical/mechanical energy; real wires also heat. Two model seconds play over six real seconds. Cross-section positions use a common scale; conductor radii and force arrows are schematic.
Status: Ready
Playback: 6 real seconds per run; read elapsed physical model time. Pause or Step for measurements.
Measurements
Load givens — then predict and run
Loading a setup earns no trial credit.
♢ DISCOVER — Field First, Force Second
DOK 1 — RecallFlip all 4 rule cards. Keep the quantities and model conditions clear.
Rule 1
Field at the other wire
Click to flip
Field at the other wire
Wire 1 produces B₁ = μ₀|I₁|/(2πd) at wire 2, tangential to a circle about wire 1 and perpendicular to the plane of the two parallel axes. This field does not point radially toward wire 1.
Rule 2
Force and reciprocal equality
Click to flip
Force and reciprocal equality
For equal interacting lengths, magnitude F = |I₂|LB₁ gives F/L = μ₀|I₁I₂|/(2πd). Interchanging the wires gives the same magnitude. If currents differ, their fields differ but the reciprocal force products match.
Rule 3
Direction and scaling
Click to flip
Direction and scaling
Same-direction currents attract and opposite-direction currents repel. The magnitude is linear in each current magnitude and inversely proportional to axis separation. Doubling both currents multiplies magnitude by four; doubling separation halves it.
Rule 4
Model and SI precision
Click to flip
Model and SI precision
The formula assumes long straight parallel wires in vacuum, with radii much smaller than separation and end/return effects negligible. μ₀ ≈ 4π×10⁻⁷ T m/A is the school approximation. The pre-2019 ampere used a two-wire force definition; the modern ampere fixes elementary charge e, not that force experiment.
All rules explored.
MISCONCEPTION ATTACK — Destroy the Myths
DOK 2 — AnalyzeChoose TRUE or FALSE for each claim. The explanation appears after an attempt; only a correct answer completes the claim.
Myth 1: “The wire carrying the larger current always experiences the larger reciprocal force.”
Correct — the claim is false.
False. Each reciprocal magnitude contains the same current product, separation and interacting length.
Myth 2: “If wire 2 has zero current, wire 1 produces zero field at its position.”
Correct — the claim is false.
False. Wire 1 still produces a field when I₁ is nonzero; wire 2’s mutual I₂L×B₁ force is zero because I₂ = 0.
Both myths corrected. Continue to the instructor questions.
✦ THE SECOND “AHA!” — Interaction and Force-per-Length Checks
DOK 2 — ApplyUse equal interacting lengths and the ideal long-wire assumptions.
Instructor Q1 — Source Field Direction
Wire 1’s field at wire 2 is:
Instructor Q2 — Opposite Currents
Opposite-direction currents in parallel wires give:
Instructor Q3 — Force per Length
I₁ = 5.0 A, I₂ = 5.0 A and d = 0.10 m. Find force magnitude per unit length.
Instructor Q4 — From Force Density to Force
F/L = 0.40 mN/m. Find the force magnitude on 0.50 m of interacting wire.
4/4 — Instructor Questions Completed
Do not confuse the tangential source field with the inward or outward force. Unequal currents still give equal reciprocal forces on equal lengths.
✎ PRACTICE — Independent Parallel-Wire Reasoning
DOK 1–3 — PracticeChallenge 1: Calculate Force per Length
Two ideal long parallel wires each carry 10 A and are separated by 1.0 m between their axes. Find the magnetic force magnitude per unit length. Use μ₀ ≈ 4π×10⁻⁷ T m/A.
Step-by-Step Solution
F/L = (2×10⁻⁷)(10)(10)/1.0 = 2.0×10⁻⁵ N/m = 20 μN/m. This is a calculation, not the modern ampere definition.
Challenge 2: Change Two Currents and Spacing
Initially I₁ = 4.0 A, I₂ = 6.0 A and d = 0.080 m. Find the initial force magnitude per length. Then double both current magnitudes and double separation. Find the new force magnitude per length; both currents remain in their original directions.
Step-by-Step Solution
Initial F/L = (2×10⁻⁷)(4)(6)/0.080 = 6.0×10⁻⁵ N/m. Scaling is (2×2)/2 = 2, giving 1.2×10⁻⁴ N/m.
Challenge 3: Audit the Unequal-Current Report
Two ideal long parallel wires carry I₁ = +12 A and I₂ = −8 A relative to the same axis direction. Their axis spacing is 0.040 m. Find the mutual force magnitude per unit length and the force magnitude on 0.50 m of either wire. A report says “the 12 A wire feels a larger force, the currents attract, wire 1’s field points radially toward wire 2, and setting I₂ to zero removes B₁.” Correct all four claims using the two-step field/force model. Explain what happens to magnitude if spacing doubles at fixed currents.
Explanation checks are indicative. Compare your reasoning with the worked solution or your teacher.
Step-by-Step Solution
F/L = (2×10⁻⁷)(12)(8)/0.040 = 4.8×10⁻⁴ N/m; F = (4.8×10⁻⁴)(0.50) = 2.4×10⁻⁴ N on each equal length. Forces are equal and opposite; opposite currents repel. B₁ is tangential around wire 1, not radial. If I₂ = 0, B₁ remains but the mutual force vanishes. Doubling d halves the force magnitude for fixed currents.
☷ CHALLENGE — Mutual Force Magnitude Changes
DOK 2 — ApplyMutual Force Magnitude Changes
Select each statement and place it in its matching category. Judge the physical conditions.
0 / 6 correct
Physics Insight
Do not confuse the tangential source field with the inward or outward force. Unequal currents still give equal reciprocal forces on equal lengths.
TEACH — The Feynman Technique
DOK 3 — TeachYour Final Mission: Explain the other wire’s tangential field, attraction/repulsion from I L×B, equal reciprocal forces despite unequal currents, and the distinction between force per length and total force.
Use simple words and at least three short sentences. This checks effort; compare your physics with the Vault or your teacher.
Type Your Explanation (≥ 3 sentences)
Draw a labelled explanation with at least three purposeful strokes. This checks effort; compare your physics with the Vault or your teacher.
Cyan pen selected.
Final reward below
Hidden exam secrets inside — Crest's private notebook.
Crest’s Secret Notebook
Mission 11.10 — Forces Between Parallel Wires
Reach the Peak of Understanding
1. Field at the other wire
Wire 1 produces B₁ = μ₀|I₁|/(2πd) at wire 2, tangential to a circle about wire 1 and perpendicular to the plane of the two parallel axes. This field does not point radially toward wire 1.
2. Force and reciprocal equality
For equal interacting lengths, magnitude F = |I₂|LB₁ gives F/L = μ₀|I₁I₂|/(2πd). Interchanging the wires gives the same magnitude. If currents differ, their fields differ but the reciprocal force products match.
3. Direction and scaling
Same-direction currents attract and opposite-direction currents repel. The magnitude is linear in each current magnitude and inversely proportional to axis separation. Doubling both currents multiplies magnitude by four; doubling separation halves it.
4. Model and SI precision
The formula assumes long straight parallel wires in vacuum, with radii much smaller than separation and end/return effects negligible. μ₀ ≈ 4π×10⁻⁷ T m/A is the school approximation. The pre-2019 ampere used a two-wire force definition; the modern ampere fixes elementary charge e, not that force experiment.
5. Two-wire motion
For equal mass per length and symmetric translation, each wire feels force per length |k|/d and the separation obeys d″ = −2k/(μd). This interaction varies as d changes; do not grow an arbitrary force arrow while holding every physical quantity fixed. Mechanical supports prevent the model from reaching d = 0.
6. School reference and modern SI
For approximately 1 A in each ideal wire at approximately 1 m, the force per length is approximately 2×10⁻⁷ N/m. Before the 2019 revision, this relation entered the ampere definition and μ₀ had an exact assigned value. Today e = 1.602176634×10⁻¹⁹ C is fixed exactly, while μ₀ is determined experimentally; the school approximation remains excellent.
7. Applications and limits
High-current conductor supports must account for magnetic forces, including changing currents and geometry. Some circuit-breaker mechanisms use magnetic effects, but not every breaker operates by two wires repelling. A real entire circuit includes return paths, stresses, resistive heating and energy exchange with sources.
Worked independent practice
C1: 2×10⁻⁵ N/m. C2: 6×10⁻⁵ N/m then 1.2×10⁻⁴ N/m. C3: 4.8×10⁻⁴ N/m and 2.4×10⁻⁴ N on each equal length, repulsive. Source fields remain when the other current is switched off.
SI-history references: NIST, Ampere: Introduction (updated 2026); BIPM, SI Base Units.
Live investigation and access
Two effectively long parallel nonmagnetic wires have equal mass per unit length μ = 0.020 kg/m and regulated steady currents. I₁ is positive out of the page; signed I₂ is positive out, negative into the page. Their cross-sections move symmetrically along x from rest; the center stays fixed. Initially separated by d₀, they obey d″ = −2k/(μd), where k = 2×10⁻⁷ I₁I₂ in SI units. Each force per length has magnitude |k|/d, so force changes during motion. A numerical velocity-Verlet integration uses 0.001 s steps. Protective supports stop inward motion at d = 0.030 m and remove kinetic energy at contact; no singular collision is modeled. The wires remain parallel; gravity and lead forces are supported and end effects neglected. Regulated sources supply or absorb electrical/mechanical energy; real wires also heat. Two model seconds play over six real seconds. Cross-section positions use a common scale; conductor radii and force arrows are schematic.
Run, Pause, Step and Reset work offline. Complete three matched measurements. Loading a preset is not completing a trial. Saved progress resumes paused. Reduced-motion Run gives a final snapshot; Step allows deliberate inspection. Hints and solutions require a genuine unsuccessful numerical attempt and never complete a task. Explanation rubrics are indicative; compare your physics with the solution or a teacher. Teaching submission checks effort rather than certifying scientific accuracy.
Course scope
A Level 9702 20.4 requires explaining the origin and direction of conductor interactions. AP Physics 2 12.3 includes long-wire fields and forces on wires; the parallel-wire equation is a derived application. Quantitative two-wire motion is enrichment, and SI history is checked against NIST/BIPM descriptions.
Sources: Cambridge International 9702 syllabus ; College Board AP Physics 2 CED. Detailed extension models are labelled in the mission.
✓ Crest’s Checklist
- I use the other source’s field.
- I measure axis separation.
- I distinguish field direction from force direction.
- I use current products and equal interacting lengths.
- I label the old ampere definition as historical.
— Crest ☆ “Reach the Peak of Understanding”
Mission 11.10 Complete! · All 10 levels cleared · PHYSICS CREST
★ Forces Between Parallel Wires Investigator
Do not confuse the tangential source field with the inward or outward force. Unequal currents still give equal reciprocal forces on equal lengths.