WONDER — The Mystery
The Same Flux Change at Different Speeds
Two coils undergo the same change in flux linkage, but one change takes less time. Their average induced e.m.f.s differ. A turning generator coil can have its largest flux exactly when its instantaneous induced e.m.f. is zero. How can both results follow one law?
Model: Choose a positive area normal and its associated positive circulation using the right-hand rule. ε = −d(NΦ)/dt is instantaneous; εaverage = −Δ(NΦ)/Δt is a signed interval average. The minus sign encodes opposition to change, not a requirement that every measured value be negative.
PREDICT — Commit to Your Answer
DOK 2 — PredictA coil’s flux linkage increases by the same amount in two trials. Trial 2 takes half the time of Trial 1. How do the magnitudes of their average induced e.m.f.s compare?
Commit to both a prediction and a reason before revealing the explanation.
Step 1: Pick your answer.
STOP! Before revealing — why did you pick that?
Correct prediction and reasoning saved.
The same linkage change in half the time gives twice the magnitude of average induced e.m.f.
▶ PLAY — A Turning Coil: Flux and E.M.F. in Real Time
DOK 2 — InvestigatePredict, measure and compare
Measure two turn counts at the same frequency, then change only frequency at one of those turn counts. Watch the coil physically rotate and compare flux, linkage and signed e.m.f.
An N-turn flat coil of area A = 0.0040 m² rotates at constant frequency f in a uniform B = 0.12 T field. The positive normal angle is θ = 2πft, initially aligned with B. Flux per turn is BA cosθ and e.m.f. is NBA(2πf)sinθ. The closed load is 12 Ω, with self-inductance and mechanical back reaction neglected because an ideal external drive fixes f. Each run lasts 6 model seconds over 6 real seconds. Coil dimensions, meter scale and charge markers are schematic. Pausing freezes model time rather than physically stopping a spinning coil; f = 0 is the stationary case.
Status: Ready
Playback: 6 real seconds per run; read elapsed physical model time. Pause or Step for measurements.
Measurements
Load givens — then predict and run
Loading a setup earns no trial credit.
♢ DISCOVER — Value, Rate and Direction
DOK 1 — RecallFlip all 4 rule cards. Keep the quantities and model conditions clear.
Rule 1
Instantaneous law
Click to flip
Instantaneous law
ε = −dλ/dt, where λ is flux linkage. For fixed N and equal-turn flux, λ = NΦ and ε = −N dΦ/dt. Derivatives describe one instant.
Rule 2
Average law
Click to flip
Average law
The signed average over an interval is −Δλ/Δt. Its magnitude need not equal the peak or the instantaneous value at the end. Oscillations can give zero signed average despite nonzero e.m.f. during the interval.
Rule 3
Lenz and a sign convention
Click to flip
Lenz and a sign convention
The induced response opposes the change producing it. A measured sign depends on chosen normal and positive circulation. Reversing the normal reverses λ and the associated sign of ε without changing the phenomenon.
Rule 4
The energy source
Click to flip
The energy source
A resistive load dissipates electrical energy. A real driven generator requires mechanical work against the electromagnetic response. The magnetic field mediates conversion; a permanent magnet is not a source of unlimited energy.
All rules explored.
MISCONCEPTION ATTACK — Destroy the Myths
DOK 2 — AnalyzeChoose TRUE or FALSE for each claim. The explanation appears after an attempt; only a correct answer completes the claim.
Myth 1: “A rotating coil’s largest flux must occur at its largest induced e.m.f.”
Correct — the claim is false.
False. For sinusoidal flux, its slope is zero at a flux extremum, so instantaneous e.m.f. is zero there.
Myth 2: “Zero signed average e.m.f. over a complete cycle means no energy can be supplied to a resistor.”
Correct — the claim is false.
False. Alternating voltage and current can deliver positive power even when their signed cycle averages vanish.
Both myths corrected. Continue to the instructor questions.
✦ THE SECOND “AHA!” — Average and Instantaneous Checks
DOK 2 — ApplyUse the stated interval, turn count and orientation convention.
Instructor Q1 — Constant Linkage
A coil maintains a nonzero constant flux linkage. What e.m.f. is induced?
Instructor Q2 — Flux Extremum
A uniformly rotating coil has Φ = BA cosωt. At maximum positive flux, instantaneous e.m.f. is:
Instructor Q3 — Average Linkage Rate
Flux linkage decreases from 0.080 Wb to 0.020 Wb in 0.30 s. Find signed average e.m.f.
Instructor Q4 — Equal Turns
A 25-turn coil’s flux per turn increases at 0.0060 Wb/s. Find signed instantaneous e.m.f.
4/4 — Instructor Questions Completed
An e.m.f. measures a rate of linkage change; flux maxima and e.m.f. maxima occur at different times in a rotating coil.
✎ PRACTICE — Independent E.M.F. Calculations and Audits
DOK 1–3 — PracticeChallenge 1: Average Induced E.M.F.
A 40-turn coil’s signed flux per turn changes from +0.0030 Wb to −0.0010 Wb over 0.20 s. Find the signed average induced e.m.f. Use the normal/circulation convention associated with the stated flux.
Step-by-Step Solution
εavg = −40(−0.0010 − 0.0030)/0.20 = +0.80 V.
Challenge 2: A Nonlinear Flux History
A stationary 75-turn coil has signed flux per turn Φ(t) = 0.0040 − 0.0010t² Wb, with t in seconds, over 0 ≤ t ≤ 2.0 s. Find signed average e.m.f. over this interval and signed instantaneous e.m.f. at t = 2.0 s.
Step-by-Step Solution
Φ(0) = 0.0040 Wb; Φ(2) = 0. Faraday’s law gives εavg = −75(−0.0040)/2 = +0.15 V. dΦ/dt = −0.0020t Wb/s, so ε(2) = −75(−0.0040) = +0.30 V.
Challenge 3: Audit the Generator Report
A 50-turn coil of area 0.0030 m² rotates at 4.0 Hz in a uniform 0.20 T field. Its positive normal angle is θ = 2πft. A report says: “Peak e.m.f. is NBA = 0.030 V; signed average e.m.f. over a full turn equals that peak; and a permanent magnet supplies unlimited electrical energy without mechanical work.” Find the correct peak e.m.f. magnitude and the signed average over one full turn. Correct all three claims and explain why increasing frequency can increase e.m.f. without creating free energy.
Explanation checks are indicative. Compare your reasoning with the worked solution or your teacher.
Step-by-Step Solution
ω = 8π rad/s; peak magnitude = NBAω = 0.030(8π) = 0.24π ≈ 0.754 V. After a complete turn linkage returns to its initial value, so signed average e.m.f. is zero. The report omits angular speed, confuses peak and signed mean, and ignores the mechanical energy supplied by the drive against the electromagnetic response. Higher frequency increases the linkage-change rate, but delivering load power requires an energy input.
☷ CHALLENGE — Which Quantity Is Being Described?
DOK 2 — ApplyWhich Quantity Is Being Described?
Select each statement and place it in its matching category. Judge the physical conditions.
0 / 6 correct
Physics Insight
An e.m.f. measures a rate of linkage change; flux maxima and e.m.f. maxima occur at different times in a rotating coil.
TEACH — The Feynman Technique
DOK 3 — TeachYour Final Mission: Explain average versus instantaneous Faraday’s law, the rotating-coil phase relation, the meaning of Lenz’s minus sign, and the energy input needed to supply a load.
Use simple words and at least three short sentences. This checks effort; compare your physics with the Vault or your teacher.
Type Your Explanation (≥ 3 sentences)
Draw a labelled explanation with at least three purposeful strokes. This checks effort; compare your physics with the Vault or your teacher.
Cyan pen selected.
Final reward below
Hidden exam secrets inside — Crest's private notebook.
Crest’s Secret Notebook
Mission 11.5 — Faraday’s Law of Induction
Reach the Peak of Understanding
1. Instantaneous law
ε = −dλ/dt, where λ is flux linkage. For fixed N and equal-turn flux, λ = NΦ and ε = −N dΦ/dt. Derivatives describe one instant.
2. Average law
The signed average over an interval is −Δλ/Δt. Its magnitude need not equal the peak or the instantaneous value at the end. Oscillations can give zero signed average despite nonzero e.m.f. during the interval.
3. Lenz and a sign convention
The induced response opposes the change producing it. A measured sign depends on chosen normal and positive circulation. Reversing the normal reverses λ and the associated sign of ε without changing the phenomenon.
4. The energy source
A resistive load dissipates electrical energy. A real driven generator requires mechanical work against the electromagnetic response. The magnetic field mediates conversion; a permanent magnet is not a source of unlimited energy.
5. Uniformly turning coil
For a constant uniform field, fixed area and constant angular speed, λ = NBA cosωt and ε = NBAω sinωt. The peak magnitude is NBA|ω|. If f = 0 there is no rotation-driven e.m.f. This formula is not valid for every generator geometry.
6. Average, peak and RMS
A full-period signed average of a sinusoidal e.m.f. is zero. Its RMS value is peak/√2 and is useful for resistive heating. RMS and average magnitude differ from signed average; a zero signed mean does not imply zero power.
7. Circuit and analogy limits
Faraday’s law supplies an e.m.f. even for an open coil; current requires a closed path and the relevant circuit dynamics. Rain intensity times projected opening area illustrates a collection rate, not accumulated water volume, and does not model current or magnetic-field energy.
Worked independent practice
C1: +0.80 V. C2: average +0.15 V and instantaneous +0.30 V at 2 s. C3: peak 0.24π ≈ 0.754 V and zero full-turn signed average; the drive supplies energy delivered to a load.
Live investigation and access
An N-turn flat coil of area A = 0.0040 m² rotates at constant frequency f in a uniform B = 0.12 T field. The positive normal angle is θ = 2πft, initially aligned with B. Flux per turn is BA cosθ and e.m.f. is NBA(2πf)sinθ. The closed load is 12 Ω, with self-inductance and mechanical back reaction neglected because an ideal external drive fixes f. Each run lasts 6 model seconds over 6 real seconds. Coil dimensions, meter scale and charge markers are schematic. Pausing freezes model time rather than physically stopping a spinning coil; f = 0 is the stationary case.
Run, Pause, Step and Reset work offline. Complete three matched measurements. Loading a preset is not completing a trial. Saved progress resumes paused. Reduced-motion Run gives a final snapshot; Step allows deliberate inspection. Hints and solutions require a genuine unsuccessful numerical attempt and never complete a task. Explanation rubrics are indicative; compare your physics with the solution or a teacher. Teaching submission checks effort rather than certifying scientific accuracy.
Course scope
9702 A Level 20.5 and AP Physics 2 12.4 cover Faraday and Lenz laws. The nonlinear time-history example and ideal uniformly rotating-coil model support rate reasoning; assumptions and current-path requirements are explicit.
Sources: Cambridge International 9702 syllabus ; College Board AP Physics 2 CED. Detailed extension models are labelled in the mission.
✓ Crest’s Checklist
- I state flux or linkage.
- I distinguish peak, signed average and instantaneous e.m.f.
- I use the correct interval.
- I keep signs tied to the chosen normal.
- I identify the source of delivered electrical energy.
— Crest ☆ “Reach the Peak of Understanding”
Mission 11.5 Complete! · All 10 levels cleared · PHYSICS CREST
★ Faraday’s Law of Induction Investigator
An e.m.f. measures a rate of linkage change; flux maxima and e.m.f. maxima occur at different times in a rotating coil.