PHYSICS CREST
Physics

Topic 2.1.3 · Gases and the Absolute Scale

Gravity in calculations: near Earth, g ≈ 9.8 m/s² (9.8 N/kg). Use the value supplied by the question, page instructions or activity; use 10 when it is specified.

Control one variable, predict the pressure response, explain the collision mechanism, then use Kelvin and $pV$ only where their exact conditions apply.

Core gas reasoningKelvin conversionSupplement Boyle lawSensor-based ATP
FIXED MASS OF GASPRESSURE pVOLUME VTEMPERATURE Tidentify change ·identify control ·predict pressurefixed mass of gasthroughout
Gas questions depend on which variable changes and which stays constant.
2
Core qualitative relationship

Heating a gas at fixed volume

  • For a fixed gas at constant volume, pressure rises with temperature because particles move faster and strike walls more energetically and frequently.
  • Extrapolation of idealised pressure data towards absolute zero is a model, not a claim that a real gas remains gaseous throughout cooling.
cooler · lowerpressurehotter · higherpressuresame fixed mass · samerigid volume
At constant volume, heating increases average speed and wall-collision effects.
constant volume: temperature ↑ → average speed ↑ → impacts more frequent and stronger → pressure ↑
cooler gashotter gassame volume andparticle number
Compare collision frequency and momentum change per collision using the stated control condition.
hotter gas: largerforce per unit area
Gas pressure comes from particle collisions exerting force on the walls.
HEATING AT FIXEDVOLUMEparticle numberconstantwall area / volumeconstantaverage speedincreasespressureincreases
Use the labelled evidence with the question.
Predict pressure when a rigid sealed gas vessel is warmed.
Collision chainHOTTER → FASTER → MORE HITS + GREATER Δp PER HIT → HIGHER p

A faster rebound gives a greater momentum change per collision; the particles themselves do not become larger.

Full explanation: particles hit the walls more frequently and with greater momentum change per collision, increasing total wall force per unit area.
Scope guard: this section requires a qualitative prediction. Do not invent a numerical $p/T$ formula unless one is explicitly provided elsewhere.
3
Core qualitative relationship

Compressing a gas at constant temperature

Compression: fixed mass and constant temperatureCompression: fixed mass and constant temperaturelarger V · lower psmaller V · higher pSame particle count and typical speeds; shorter journeys between walls.
At constant temperature, reducing volume increases collision frequency.
compression atconstant temperatureshorter travel betweenwall collisions
Use the stated temperature and mass conditions before predicting pressure.
constant temperature: volume ↓ → collision frequency ↑ → pressure ↑
Compression: fixed mass and constant temperatureCompression: fixed mass and constant temperaturelarger V · lower psmaller V · higher pSame particle count and typical speeds; shorter journeys between walls.
Compare collision frequency and momentum change per collision using the stated control condition.
WHAT STAYS THE SAME?average particle speedapproximately constantaverage force percollisionapproximately constantcollision frequencyincreases oncompressionpressureincreases
Use the labelled evidence with the question.
Interactive · Compression Predictor

Move the gas volume

100% volume · reference pressure
Constant-temperature distinction: do not claim stronger individual collisions. The key change is more frequent collisions because the travel distance is smaller.
Slow-compression reason: waiting for thermal equilibrium helps the gas remain at the stated temperature. Rapid compression can warm it.
4
Two zeros · equal-sized intervals

The Kelvin temperature scale

  • Kelvin and Celsius have equal-sized intervals but different zeros.
  • At this level use T/K = temperature/°C + 273.
  • A rise of 10 °C is a rise of 10 K, but a temperature of 10 °C is not 10 K.
  • Absolute zero is approximately −273 °C, the lower limit of the thermodynamic temperature scale.
127 °C = 400 K-73 °C = 200 K-273 °C = 0 K27 °C = 300 K
Kelvin uses K without a degree symbol.
$T/\mathrm{K}=\theta/°\mathrm{C}+273$
127 °C = 400 K-73 °C = 200 K-273 °C = 0 K−23 °C = 250 K
Kelvin and Celsius intervals are equal in size but have different zero points.

Celsius → kelvin

Add 273.
$35 °C=308 K$.

Kelvin → Celsius

Subtract 273.
$310 K=37 °C$.

NOTATION RULESkelvin value300 Kwrong form300 °Kabsolute zero0 K = −273 °Ctemperature rise1 K = 1 °C interval
Use the labelled evidence with the question.
-273 °C · absolutezero0 K = −273 °C
Absolute zero is the lowest possible temperature.
Interactive · Temperature Bridge

Enter a Celsius temperature

27 °C = 300 K
Sign checkK IS 273 HIGHER NUMERICALLY

Room temperature must be roughly 300 K, not a negative kelvin value.

Unit trap: write K, never °K. Keep the degree sign with °C.

Pause · explain it yourself

Does heating from 20 to 40 °C double absolute temperature?

5
Supplement constant-product law

Boyle’s law

  • For fixed mass at constant temperature, pV is constant.
  • Hence p₁V₁ = p₂V₂.
  • Reducing volume increases pressure because wall collisions become more frequent.
  • Average kinetic energy remains unchanged if temperature stays fixed.
  • Use the same pressure units on both sides and the same volume units on both sides; cm³ can be used consistently because the ratio cancels.
  • Pressures must be absolute, not an unqualified gauge-pressure reading.
  • A slowly adjusted apparatus and settling time help maintain temperature.
  • Leakage invalidates the fixed-mass condition.
Compression: fixed mass and constant temperatureCompression: fixed mass and constant temperaturelarger V · lower psmaller V · higher pSame particle count and typical speeds; shorter journeys between walls.State 1: 100 kPa, 60 cm³. State 2: 150 kPa, 40 cm³.
At constant temperature, reducing volume increases collision frequency.
$pV=\text{constant}$    so    $p_1V_1=p_2V_2$
GAS DATApressure / kPavolume / cm³10060120501504020030
Check whether pressure × volume is approximately constant.
CONDITIONSmass / amountfixedtemperatureconstantunitsmatching across statesreadingsequilibrium
Use the labelled evidence with the question.
state 1 → state 2label p₁,V₁ and p₂,V₂before substituting
Use the stated temperature and mass conditions before predicting pressure.
Interactive · Boyle Calculator

Find the second pressure

p₂ = 200.00 kPa
Factor checkV DOWN → p UP

If your calculation makes both pressure and volume fall at constant temperature, recheck the rearrangement.

Unit efficiency: kPa with kPa and cm³ with cm³ is valid in $p_1V_1=p_2V_2$. Convert only when corresponding units differ.

Pause · explain it yourself

What happens to absolute pressure when volume halves under Boyle’s-law conditions?

Pause · explain it yourself

Why wait after rapid compression before taking a Boyle-law reading?

A fixed mass of gas is compressed at constant temperature. What stays unchanged?

Your turn · Extended: 80 cm³ of gas at 90 kPa is compressed to 60 cm³ at constant temperature. Find final pressure.

Decimals and scientific notation are accepted. Compatible units are accepted.

6
Curve · reciprocal · product

Gas-law graphs

  • A pressure–volume graph for constant temperature is a downward curve, not a straight descending line.
  • Inverse proportion means constant product, not simply one quantity rising while the other falls.
  • A graph of pressure against 1/volume is straight through the origin in the ideal model.
  • In an experiment, seal the gas, measure volume and pressure, allow temperature to settle and check for leakage.
  • Repeat measurements where appropriate.
  • Explain systematic deviations using controlled conditions rather than assuming every non-exact product is random error.
volumepressurep against V: inversecurve
Use the graph shape to identify the relationship.
1 / volumepressurep against 1/V:straight line
Use the graph shape to identify the relationship.
CHECK THE PRODUCTpressure / kPavolume / cm³8090100721206016045
Check whether pressure × volume is approximately constant.
Compression: fixed mass and constant temperatureCompression: fixed mass and constant temperaturelarger V · lower psmaller V · higher pSame particle count and typical speeds; shorter journeys between walls.
At constant temperature, reducing volume increases collision frequency.
GRAPH DECODERp vs Vdecreasing curvep vs 1/Vstraight throughorigingradient of p vs 1/VpV constantanomalyproduct far fromcluster
Use the labelled evidence with the question.
Choose the $p$ against $V$ graph at constant temperature.
Interactive · Product Checker

Test one pressure–volume pair

pV = 6000 kPa cm³
Graph language: “pressure is inversely proportional to volume” is stronger than “pressure decreases.” Support it using constant products or a straight $p$–$1/V$ plot.
Do not join dot-to-dot: experimental graphs use a smooth best-fit curve or best-fit line; anomalies should not control the trend.
7
Label · condition · equation · solve · sense-check

Gas-law calculations

STATE LABELSstate 1p₁=90 kPa ·V₁=80 cm³state 2p₂=120 kPa ·V₂=?conditionsfixed mass · constantT
Use the labelled evidence with the question.
Compression: fixed mass and constant temperatureCompression: fixed mass and constant temperaturelarger V · lower psmaller V · higher pSame particle count and typical speeds; shorter journeys between walls.State 1: 90 kPa, 80 cm³. State 2: 120 kPa, V₂ unknown.
At constant temperature, reducing volume increases collision frequency.

Worked: find the second volume

$p_1V_1=p_2V_2$

$V_2=(90×80)/120=60\text{ cm}^3$.

Sense-check: pressure rose, so volume fell.

127 °C = 400 K-73 °C = 200 K-273 °C = 0 K42 °C = 315 K
Kelvin uses K without a degree symbol.
COMPLETE BY CONSTANTPRODUCTpressure / kPavolume / cm³90801206014450?45
Check whether pressure × volume is approximately constant.
  1. Label both gas states.
  2. Write fixed mass and constant temperature.
  3. Make corresponding units match.
  4. Substitute into $p_1V_1=p_2V_2$ and rearrange.
  5. Sense-check inverse direction and attach a unit.
Pressure rises from 90 to 120 kPa at constant T. Predict $V_2$ before calculating.
Cross-multiplication trap: keep each pressure with its same-state volume. Use a labelled table if the wording gives final data first.
Precision: retain extra digits during working, then round to the precision justified by the data.
8
Alternative to Practical

Design gas investigations around equilibrium, leaks and controlled compression

pressuresensorrecord p / kPaclamped · needle-free· modest compression
Use pressure-rated apparatus and keep temperature as constant as possible.
volumepressureplot mean p against V
Complete or interpret the labelled axes.
1 / volumepressureplot mean p against1/V
Complete or interpret the labelled axes.
pressure sensorpressure + temperatureloggerteacher-set mild baths· fixed rigid volume
A supervised low-risk setup can investigate pressure against temperature at constant volume.
ATP PROCESSINGp–V testmean p, 1/V, pVp–T testqualitative trend onlyequilibriumwait for stablereadingsrepeatup/down sequence +means
Use the labelled evidence with the question.

Volume investigation

Change marked syringe volume; control gas mass and temperature. Use an absolute-pressure reading, then plot $p$ vs $V$ and $p$ vs $1/V$.

Temperature investigation

Use a rigid sealed rated vessel in mild supervised baths. Control mass and volume; record steady pressure qualitatively against temperature.

IssueLikely effectImprovement
rapid compressiongas warms; pressure too high for constant-T testcompress slowly and wait for equilibrium
dead volume in tubingeffective volume larger than syringe readingmeasure/include connection volume
small leakgas mass driftsleak-check and compare return readings
plunger parallaxvolume too high/lowread mark at eye level from a fixed reference
pressure typea gauge-pressure reading does not satisfy the Boyle-law product directlyuse an absolute-pressure sensor/readout
Safety: use pressure-rated, needle-free, securely clamped apparatus; modest compression only; keep faces out of the plunger line. For temperature work, use supervised mild water baths—never flame, boiling water or strong heating of a sealed gas.
High-level evaluation: name whether an error changes mass, temperature, effective volume or sensor zero, then predict its effect on the relationship.
1
The first move is always the condition

Pressure, volume and temperature form a three-variable decision map

For a fixed mass of gas, pressure can change because temperature changes, volume changes, or both. A fair relationship changes one cause while controlling the other.

FIXED MASS OF GASPRESSURE pVOLUME VTEMPERATURE Tchange one · controlone · observe pressurecontainer sealed:fixed gas mass
Gas questions depend on which variable changes and which stays constant.
movable wall changesvolumetemperature conditionmust be stated
Use the stated temperature and mass conditions before predicting pressure.
lower temperaturehigher temperaturerigid containers:constant volume
At constant volume, heating increases average speed and wall-collision effects.
CONDITION DECODERrigid vesselconstant volumeslow piston + thermalequilibriumconstant temperaturesealed apparatusfixed gas masspressureresponse variable
Use the labelled evidence with the question.
In a rigid sealed vessel being warmed, which gas variable is held constant by rigidity?
Question openerFIXED MASS · WHAT CHANGES? · WHAT IS FIXED?

Write the condition before choosing a relationship.

Condition language earns marks: “for a fixed mass of gas at constant volume…” or “…at constant temperature.”
Two-variable trap: if temperature and volume both change, one simple qualitative rule cannot isolate the pressure effect.
9
Last-minute examiner sheet

Gases and Absolute Scale Master Sheet

FIXED MASS OF GASPRESSURE pVOLUME VTEMPERATURE Tchange one · controlone · explaincollisionsfixed gas mass
Gas questions depend on which variable changes and which stays constant.
cooler · lower photter · higher pconstant volume
At constant volume, heating increases average speed and wall-collision effects.
Compression: fixed mass and constant temperatureCompression: fixed mass and constant temperaturelarger V · lower psmaller V · higher pSame particle count and typical speeds; shorter journeys between walls.
At constant temperature, reducing volume increases collision frequency.
127 °C = 400 K-73 °C = 200 K-273 °C = 0 KT/K = θ/°C + 273
Kelvin uses K without a degree symbol.
volumepressurep–V inverse curve
Use the graph shape to identify the relationship.

Equation set

$T/\mathrm{K}=\theta/°\mathrm{C}+273$
$pV=\text{constant}$ · $p_1V_1=p_2V_2$

Boyle conditions: fixed mass and constant temperature.

Pressure type: Boyle-law calculations use gas pressure on an absolute scale. In practical work, use an absolute-pressure sensor/readout.

Constant volume

Hotter → faster → more frequent and stronger impacts → higher pressure.

Constant temperature

Smaller volume → shorter paths → more frequent impacts → higher pressure.

Final stripCONDITION → COLLISIONS → p · K = °C + 273 · pV

State the condition before every prediction or calculation.

Final check · When volume halves at constant temperature, what happens to pressure?
It doubles because $pV$ remains constant.
Interactive mastery: 0 / 7 explored

Complete all seven explorers, then enter the independent question banks.