PHYSICS CREST
Physics

Topic 4.5 · Electromagnetic Effects

Gravity in calculations: near Earth, g ≈ 9.8 m/s² (9.8 N/kg). Use the value supplied by the question, page instructions or activity; use 10 when it is specified.

Track what changes, label field–current–motion–force directions, read the coil position, then let ratios and squared-current loss finish the calculation.

Induction & fieldsGenerator & motorTransformer ratiosLow-voltage ATP
ELECTROMAGNETIC-EFFECTS DECODERFIELD CHANGESinduction /generatorSTEADY CURRENT +FIELDforce / motorA.C. + TWO COILStransformerCHANGE?CURRENT?COILS?CHANGE · CURRENT · COILS
Classify the trigger first; the correct law and direction rule then become much easier to see.
2
Change of linkage is the cause

Electromagnetic induction

  • Induction requires a conductor moving across a field or a changing field linking a coil.
  • A stationary magnet and stationary coil do not maintain induced e.m.f. Stronger fields, faster change and more coil turns can increase induced e.m.f. Current needs a closed circuit; an open circuit can still have e.m.f.
SNGtowards coilmeter: right
Approach: the centre-zero meter deflects while linkage changes.
SNGheld stillmeter: zero
Hold still: the pointer returns to zero even with the magnet inside the coil.
SNGaway from coilmeter: left
Withdraw: the change reverses, so the induced polarity reverses.
INDUCED E.M.F. MAGNITUDEfaster motion↑more turns↑stronger field↑speed · turns · field strength
Faster change, more turns and a stronger field increase the magnitude of the induced e.m.f.
Induced e.m.f. exists when magnetic linkage changes.
Magnitude depends on how rapidly the linkage changes; direction depends on the direction of that change.
  1. Look for relative motion or a changing magnetic field.
  2. Decide whether linkage is increasing, decreasing or constant.
  3. Use speed, turns and field strength only for size.
  4. For direction, work out which induced effect would oppose the change.
Interactive · Induction response

Build the peak meter response

relative peak = +9.00 units
ChangeMagnitudePolarity
move fasterlargerunchanged if motion direction is unchanged
more turnslargerunchanged
stronger magnetlargerunchanged
reverse motion or polesame if conditions matchreversed
Magnitude mnemonicS · T · F = SPEED · TURNS · FIELD

Ask “how fast?”, “how many links?” and “how strong?”.

Full-mark explanation: “The magnetic field linking the coil changes more rapidly, so a larger e.m.f. is induced.” State the changing quantity—not merely “the magnet moves”.
Quick Check · What does each part of a centre-zero reading show?
The side of zero shows polarity/current direction. The distance from zero shows magnitude.

Pause · explain it yourself

Why does holding a magnet still inside a stationary coil not produce continuous voltage?

3
The induced effect fights the change

Direction of induction

SNapproachingnear coil face = Ninduced force opposeschangeCHANGE → OPPOSE → choose the pole/ force
Approaching N: the near coil face becomes N, producing repulsion that opposes the approach.
SNmoving awaynear coil face = Sinduced force opposeschangeCHANGE → OPPOSE → choose the pole/ force
Receding N: the near coil face becomes S, producing attraction that opposes separation.
GENERATOR DIRECTION MAPFIELD →MOTION ↑?INDUCED Ithe three directions are mutuallyperpendicular
Generator rule: magnetic field, conductor motion and induced conventional current are mutually perpendicular.
REVERSAL LEDGERreverse motion onlyinduced direction reversesreverse field onlyinduced direction reversesreverse bothdirection unchangedfaster, same directionsame polarity; larger size
Treat direction and magnitude as two separate ledgers.

The induced effect opposes the change that causes it. This is often called Lenz's law. Do not say that it simply “opposes the magnetic field”.

  1. Name the approaching or receding magnet pole.
  2. Ask what force would oppose that change: repel an approach, attract a retreat.
  3. Choose the near coil pole that creates that force.
  4. If asked for current, convert the pole into a current direction using the solenoid rule.
Which near pole opposes an approaching N pole?
Direction mnemonicCHANGE → OPPOSE → DIRECTION

State the change, select the opposing force, then infer pole/current.

Equivalent-change shortcut: reversing both magnet pole and motion can preserve the same change of field linkage and therefore the same induced deflection.
Hand-rule trap: use conventional current. For electron motion, reverse the electron-velocity direction before applying a conventional-current rule.
Quick Check · N approaches and is then pulled away at the same speed. Compare readings.
The deflections are on opposite sides of zero. Their peak magnitudes can be equal if the positions, speeds and all other conditions match.
4
Rotation makes the linkage repeat

The a.c. generator

  • A generator takes mechanical input and produces electrical output.
  • Slip rings connect a rotating a.c. coil without reversing external connections each half-turn.
  • Peak e.m.f. occurs at fastest linkage change, not greatest linkage.
SIMPLE A.C. GENERATORNSplane ⟂ Bbrushesslip ringsrotation
Plane perpendicular to the field: the field linking the coil is momentarily changing at zero rate, so e.m.f. is zero.
SIMPLE A.C. GENERATORNSplane ∥ Bbrushesslip ringsrotation
Plane parallel to the field: the field linking the coil changes fastest, so the magnitude of induced e.m.f. is maximum.
GENERATOR E.M.F. AGAINST TIMEte.m.f.zeropeakzerotroughzero
One rotation of a simple two-pole generator produces one complete alternating cycle.
GENERATOR PARTSrotating coilchanges magnetic linkagetwo slip ringsremain connected to coilendsstationary brushesconnect to external circuitmechanical inputelectrical output
Slip rings maintain contact; the rotating motion causes polarity reversal.

At zero e.m.f.

The plane of the coil is perpendicular to field lines. The magnetic field linking the coil is at an extreme, but momentarily is not changing.

At maximum |e.m.f.|

The plane of the coil is parallel to field lines. The field linking the coil is changing at its greatest rate.

Interactive · Generator position explorer

Connect angle, graph and speed

angle 90° · relative e.m.f. +1.00 · frequency factor 1.00
ChangeGraph amplitudeFrequencyPolarity at same position
rotate fasterincreasesincreasessame
stronger field / more turnsincreasesunchangedsame
reverse rotation / swap polesunchanged if sizes matchunchangedreverses
Position mnemonicPLANE ∥ FIELD → PEAK · PLANE ⟂ FIELD → ZERO

Read “plane of coil” carefully; confusing it with the normal reverses the answer.

Component precision: two complete slip rings maintain separate contact with the rotating coil. They do not create the alternating reversal—the changing motion through the field does.
Linkage trap: the greatest field linkage does not mean the greatest induced e.m.f. Induced e.m.f. depends on how quickly the magnetic field linking the coil changes.
Quick Check · Faster rotation changes which two graph features?
The peak magnitude increases and the peaks occur more often, so frequency increases.
5
Thumb = conventional current

Magnetic field of a straight wire

  • A straight current has circular magnetic field lines, related by the right-hand grip rule to conventional current.
FIELD AROUND A STRAIGHT WIRE•anticlockwisecurrent out •field is stronger nearer the wire
Current out of the page (dot): field circles anticlockwise.
FIELD AROUND A STRAIGHT WIRE×clockwisecurrent into ×field is stronger nearer the wire
Current into the page (cross): field circles clockwise.
FIELD AROUND A STRAIGHT WIRE•anticlockwisePQcurrent out •field is stronger nearer the wire
At the same current, the nearer point P is in the stronger field.
DOT–CROSS CODE•arrow tip coming towardsyou×arrow tail moving awaythumbconventional currentcurled fingersmagnetic-field direction
Decode dot/cross before using the right-hand grip rule.

Field lines around a long straight wire are concentric circles centred on the wire. Their direction reverses when current reverses. Their crowding—and therefore field strength—increases with current and decreases with distance.

Interactive · Right-hand grip

Reverse the conventional current

anticlockwise · relative field strength 2.00
EvidenceConclusion
arrows circle clockwisecurrent is into the page
field reversescurrent direction reversed
field lines closer / compass turns morefield is stronger
same distance, double currentfield is stronger; direction unchanged
Page codeDOT COMES OUT · CROSS GOES IN

Imagine the point and feathers of an arrow.

Pattern plus direction: “concentric circles centred on the wire” earns pattern; “clockwise/anticlockwise by the right-hand grip rule” earns direction.
Radial-line trap: the field is not directed towards or away from the wire. It is tangential to circles around it.
Quick Check · Current emerges from the page. Field at the top of the wire?
Anticlockwise means the field arrow points left at the top of the circular path.
6
A wrapped wire behaves like a bar magnet

Magnetic field of a solenoid

  • A solenoid has a bar-magnet-like field, approximately uniform inside a long coil.
  • More current or more turns per length strengthens it; current reversal reverses poles.
Solenoid field · reverse current to swap N and SSolenoid field · reverse current to swap N and SSNInside: S → N. Outside: N → S. A compass follows the local field.Schematic pattern for a long coil; arrows show magnetic field, not current.
Inside a long solenoid, close parallel field lines show a strong, nearly uniform field.
Solenoid field · reverse current to swap N and SSolenoid field · reverse current to swap N and SNSInside: S → N. Outside: N → S. A compass follows the local field.Schematic pattern for a long coil; arrows show magnetic field, not current.
Reverse current: every field arrow reverses and the N/S ends swap.
Solenoid field · reverse current to swap N and SSolenoid field · reverse current to swap N and SSNInside: S → N. Outside: N → S. A compass follows the local field.Schematic pattern for a long coil; arrows show magnetic field, not current.
More turns per length, larger current and a soft-iron core strengthen an electromagnet.
Solenoid field · reverse current to swap N and SSolenoid field · reverse current to swap N and SSNInside: S → N. Outside: N → S. A compass follows the local field.Schematic pattern for a long coil; arrows show magnetic field, not current.
A plotting compass reveals direction at each grid point; iron filings reveal pattern but not arrow direction.

Direction

Grip the solenoid with right-hand fingers following conventional current around its turns. The thumb points towards the N pole.

Strength

A larger current gives a stronger magnetic field. Reversing the current reverses the field direction.

Interactive · Solenoid current

Change current magnitude or direction

relative field strength 1.20 · right end N
ChangeStrengthDirection
increase current magnitudeincreasessame
decrease current magnitudedecreasessame
reverse currentabout unchanged for the same magnitudereverses
Exam ruleMAGNITUDE → STRENGTH · DIRECTION → FIELD DIRECTION

Keep these two effects separate when explaining a changed current.

Field-map wording: use several compass positions; mark the direction of the needle; move the compass so its tail starts at the previous head; repeat to build a field line; repeat from different starting points.
ATP precision: keep current fixed while mapping. Switch on briefly for each observation to reduce coil heating, which otherwise changes the current.
Quick Check · Why is soft iron preferred for a relay core?
It magnetises strongly when current flows and loses most of its magnetism when current stops, so the armature can release.

Pause · explain it yourself

What happens to solenoid poles when current reverses?

7
Follow current → field → motion

Relays and loudspeakers

RELAY: TWO SEPARATE CIRCUITScontrol coilarmatureseparate outputcontactscontacts at rest
At rest, the armature and contacts occupy their normal positions.
RELAY: TWO SEPARATE CIRCUITScontrol coilarmatureseparate outputcontactscontacts changed
Coil current magnetises the core, attracts the armature and changes the separate contacts.
Moving-coil loudspeaker · one current directionMoving-coil loudspeaker · one current directionpermanentmagnetfixedconecoilforce and cone motion →Alternating current reverses the force each half-cycle.
One current direction gives a force on the coil in one direction.
Moving-coil loudspeaker · reversed currentMoving-coil loudspeaker · reversed currentpermanentmagnetfixedconecoilforce and cone motion ←Alternating current reverses the force each half-cycle.
When alternating current reverses, the coil force reverses and the cone vibrates.

Relay chain

control current → magnetic field → soft-iron core magnetised → armature moves → contacts change

Speaker chain

alternating current → alternating magnetic force → coil and cone vibrate → pressure variations

Key distinction

A relay switches a separate circuit. A speaker continuously converts a changing signal into motion.

Choose a device description.
InputMagnetic actionMechanical actionOutput
relay-coil currentcore becomes electromagnetarmature movescontacts switch
audio a.c.force on coil reversescone vibratessound wave
Application chainRELAY CHANGES CONTACTS · SPEAKER CHANGES PRESSURE

Name the magnetic stage and the mechanical stage for full marks.

Why a relay? A small control current can switch a separate circuit that may use a different current or voltage, while the circuits remain electrically isolated.
Steady-current trap: steady d.c. gives a steady speaker force after switch-on, not continuous vibration and therefore not a continuous tone.
Quick Check · Why should a relay core not retain strong magnetism?
Retained magnetism could keep the armature attracted after control current stops, so the contacts might not return correctly.
8
F, B and I are at right angles

The motor effect

  • The motor effect is force on a current-carrying conductor in a field.
  • Field, current and force are mutually perpendicular in the standard arrangement.
  • Reversing one of current or field reverses force; reversing both preserves force direction.
  • For a charged beam, conventional positive-charge motion sets the current direction; negative charges reverse this relationship.
CURRENT-CARRYING WIRE IN A FIELDNSmagnetic fieldcurrent×force is perpendicular to fieldand current
Example direction map: field left to right and current upwards give force into the page.
MOTOR DIRECTION MAPFIELD B →CURRENT I ↑×FORCE INTO PAGEthe three directions are mutuallyperpendicular
Fleming left hand links magnetic field, conventional current and force.
CURRENT-CARRYING WIRE IN A FIELDNSmagnetic fieldcurrent•force is perpendicular to fieldand current
Reverse only current: the force reverses out of the page.
MOTOR-EFFECT REVERSALSreverse current onlyforce reversesreverse field onlyforce reversesreverse bothforce unchanged
Use a reversal ledger before visualising the new direction.

A current-carrying conductor in a magnetic field can experience a force. Use the relative directions of conventional current, magnetic field and force. Reversing only the current or only the field reverses the force direction.

Interactive · Reversal checker

Predict the new force direction

force direction normal
  1. Mark the field from N to S.
  2. Use conventional current, not electron motion.
  3. Hold field and current as the two known directions.
  4. The force is perpendicular to both; use dot/cross if it enters or leaves the page.
Rule mnemonicLEFT HAND = MOTOR · RIGHT HAND = GENERATOR

Motor: current causes force. Generator: motion causes current.

Charged-particle beams: use the force–field–current direction rule. For electrons, reverse the electron-motion direction first because conventional current is opposite to electron motion. Or find the force on a positive charge and reverse it.
Poles alone are incomplete: always draw or state the magnetic field from N to S before deciding the force.
Quick Check · Both current and field reverse. New force?
The force stays in its original direction because reversing both current and field gives two direction reversals, which cancel.
9
Force pair → turn → swap → same turn

The d.c. motor

  • A d.c. motor instead uses supplied current and a split-ring commutator to reverse coil current each half-turn, maintaining the turning sense.
SIMPLE D.C. MOTORNSbrushbrush•×FFsplit ring + brushes
Opposite forces on the two active coil sides form a couple and produce a turning effect.
COMMUTATOR TIMINGbefore half-turncurrent A → Bafter half-turncurrent B → Acoil current reverses · turningdirection stays the same
Every half-turn the split-ring commutator reverses coil current, preserving the rotational direction.
SIMPLE D.C. MOTORNSbrushbrushidentify the components
Component recognition: the split ring rotates with the coil; brushes remain stationary.
TURNING-EFFECT LEVERSmore coil turnslarger turning effectlarger currentlarger turning effectstronger fieldlarger turning effectreverse supplyrotation reverses
State the allowed factor and the physical quantity it changes.
  1. Current enters through a brush and one half of the split ring.
  2. The two coil sides carry current in opposite directions.
  3. Forces on those sides are opposite and form a turning couple.
  4. After half a turn, the split ring swaps brush contact and reverses coil current.
  5. The forces swap sides, so the turning effect continues in the same rotational direction.
Which description identifies the commutator?
PartMoves?Function
coil and axlerotatereceive turning effect
split-ring halvesrotatereverse coil connection every half-turn
brushesstationarysliding contact to the supply
field magnetsstationaryprovide external magnetic field
Motor sequenceFORCE PAIR → TURN → SWAP → SAME TURN

The current reverses in the coil so the rotation does not reverse.

Do not say only “the commutator keeps it spinning”. State what it reverses, when it reverses it, and why the turning direction remains unchanged.
Ring trap: a d.c. motor uses a split ring. A simple a.c. generator uses two complete slip rings.
Quick Check · Three ways to increase motor turning effect?
Increase the number of turns, the current, or the magnetic-field strength.
10
A changing field links two coils

How a transformer works

  • Primary and secondary coils are linked by a soft-iron core.
  • Alternating primary current creates changing magnetic linkage and induces secondary e.m.f. Steady d.c. gives no sustained transformer output after switching transients.
Transformer · electrically separate coils, shared soft-iron coreTransformer · electrically separate coils, shared soft-iron coreprimarymore turnshigh V a.c.secondaryfewer turnslow V a.c.Shown turns represent the ratio; the core guides the changing magnetic field.
Step-down transformer: the secondary has fewer turns and a smaller voltage.
Transformer · electrically separate coils, shared soft-iron coreTransformer · electrically separate coils, shared soft-iron coreprimaryfewer turnslow V a.c.secondarymore turnshigh V a.c.Shown turns represent the ratio; the core guides the changing magnetic field.
Step-up transformer: the secondary has more turns and a larger voltage.
TRANSFORMER CAUSAL CHAINa.c. in primarychanging currentsoft-iron corechanging fieldsecondary linkedchanging field linkageoutputinduced a.c.e.m.f.needs a changing field
The soft-iron core carries a changing magnetic field that links both coils.
TRANSFORMER CAUSAL CHAINa.c. in primarychanging currentsoft-iron corechanging fieldsecondary linkedchanging field linkageoutputinduced a.c.e.m.f.steady d.c. → no continuousoutput
After switching, steady d.c. makes a steady core field, so there is no continuous secondary e.m.f.
  1. An alternating current flows in the primary.
  2. It creates a changing magnetic field in the soft-iron core.
  3. The changing field links the secondary coil.
  4. The changing linkage induces an alternating e.m.f. across the secondary.

Construction

Two separate insulated copper coils are wound on a shared soft-iron core. There is no direct electrical connection between the windings.

Why soft iron?

It magnetises and demagnetises readily, guiding the changing field through both windings.

What physically links the windings?
Causal mnemonicA.C. → CHANGE → LINK → INDUCE

Alternating current changes the core field; the linked change induces secondary e.m.f.

Four-link answer: mention alternating primary current, changing core field, linkage to secondary, and induced alternating secondary e.m.f.
D.C. trap: d.c. does create a magnetic field. The problem is that after the switching moment the field is steady, so it cannot maintain induction.
Quick Check · Are primary and secondary joined by a conducting wire?
No. They are electrically separate. Energy transfers through the changing magnetic field in the shared core.
Which situation can continuously operate a simple transformer?

11
Match every primary with p and secondary with s

Transformer ratios

  • Vs/Vp = Ns/Np relates voltage and turns.
EQUATION ROUTEVₚ / Vₛ = Nₚ / NₛIₚVₚ = IₛVₛput matching p and s valuestogether
The voltage ratio equals the turns ratio; equal input/output power applies only to an ideal transformer.
Transformer · electrically separate coils, shared soft-iron coreTransformer · electrically separate coils, shared soft-iron coreprimary600 turns240 V a.c.secondary150 turns? V a.c.Shown turns represent the ratio; the core guides the changing magnetic field.
Worked visual: fewer secondary turns means a step-down output.
WORKED VOLTAGE ROUTEVₛ / VₚNₛ / NₚVₛ / 240150 / 600Vₛ60 Vtypestep-down
Keep corresponding quantities on the same side of the ratio.
IDEAL POWER ROUTEsecondary12 V · 4.0 Aoutput power48 Wprimary voltage240 Vprimary current0.20 A
Find power first when the current calculation feels crowded.
$\dfrac{V_p}{V_s}=\dfrac{N_p}{N_s}$    and for an ideal transformer    $I_pV_p=I_sV_s$
Interactive · Transformer solver

Turns, voltage and ideal current

Vₛ = 60.00 V · ideal Iₚ = 1.00 A · step-down
  1. Mark which coil is primary: it receives the input.
  2. Write one consistent ratio before substituting.
  3. Use the turns ratio to calculate voltage.
  4. Only if ideal / 100% efficient, equate input and output power.
  5. Sense-check: step-up voltage must pair with step-down current.
TransformerTurnsVoltageIdeal load current
step-up$N_s>N_p$$V_s>V_p$$I_s<I_p$
step-down$N_s<N_p$$V_s<V_p$$I_s>I_p$
Ratio mnemonicVOLTS FOLLOW TURNS · IDEAL CURRENT GOES OPPOSITE

More secondary turns means more secondary voltage, but less secondary current at equal power.

Ratio flip trap: $V_p/V_s$ must pair with $N_p/N_s$. Never mix a primary numerator with a secondary-turn numerator.
Quick Check · A transformer raises voltage fourfold. Ideal current change?
The secondary current is one quarter of the primary current because input and output powers are equal.
Your turn · Extended: an ideal transformer has Np = 600, Ns = 150 and Vp = 24 V a.c. Find Vs.

Decimals and scientific notation are accepted. Compatible units are accepted.

12
High V makes current small at fixed power

High-voltage transmission

  • Ideally VpIp = VsIs, so stepping voltage up steps current down for the same power.
  • Cable heating loss is I²R.
  • High-voltage transmission helps because it reduces current at a given transmitted power, not because cable resistance disappears.
  • A step-up transformer cannot create power; real transformers also have losses.
HIGH-VOLTAGE TRANSMISSIONgeneratorstep-uptransmissioncablesstep-down +usershigh Vlow Ilow I²R heating loss
Generation → step up → long high-voltage cables → step down near users.
CABLE-LOSS COMPARISONcase AI = 10 Aloss = 400 Wcase BI = 2 Aloss = 16 W
Reducing current by a factor of five reduces cable heating loss by a factor of twenty-five.
TRANSMISSION ROUTEP = IV → I = P / VP loss = I²Rsame transmitted power ·same cable R
Use fixed transmitted power to find current, then square current for cable loss.
SQUARED-FACTOR CHECKvoltage ×3current ÷3current ÷3loss ÷9voltage ×5current ÷5current ÷5loss ÷25
At fixed power and resistance, cable loss varies inversely with voltage squared.
  1. For the transmitted power, calculate cable current using $I=P/V$.
  2. Calculate heating loss using $P_{loss}=I^2R$.
  3. If voltage changes by a factor, current changes by the inverse factor.
  4. Square the current factor to compare losses.
Interactive · Grid-loss comparator

Raise voltage, watch $I^2R$ collapse

current = 10.00 A · cable loss = 400.00 W
Worked comparison: Transmit $2.0\,MW$ through $4.0\,Ω$. At $20\,kV$, $I=100\,A$ and loss $=40\,kW$. At $200\,kV$, $I=10\,A$ and loss $=0.40\,kW$. Ten times the voltage gives one hundredth of the loss.
Grid mnemonicHIGH V → LOW I → MUCH LOWER I²R

The word “much” matters because the current is squared.

Complete advantage: for the same transmitted power, higher voltage means lower current; lower current gives less $I^2R$ heating, so less energy is wasted in the cables.
Safety claim trap: high transmission voltage is not safer to touch. Its advantage is efficiency; voltage is stepped down near consumers.
Quick Check · Cable current becomes one quarter. Loss factor?
$P_{loss}$ becomes $(1/4)^2=1/16$ of its original value if cable resistance is unchanged.

Pause · explain it yourself

Why step up voltage for long-distance transmission?

13
Alternative to Practical

ATP Lab Lens · define the measurable quantity, control geometry, repeat and link every improvement

INDUCTION SPEED INVESTIGATIONSNlight gatesdata loggerspeed at coil · peak |e.m.f.|
Induction ATP: measure speed near the coil, capture peak magnitude and repeat at each setting.
Solenoid field · reverse current to swap N and SSolenoid field · reverse current to swap N and SSNInside: S → N. Outside: N → S. A compass follows the local field.Schematic pattern for a long coil; arrows show magnetic field, not current.
Field mapping ATP: mark compass direction at each point while keeping current fixed.
FORCE-CURRENT INVESTIGATIONdigital balanceNSfixed wire ⟂ field · current out ••ammeter + variable resistorcurrent-limited low V d.c.zero balance · brief current · mean change
Motor-effect ATP: a balance can measure the equal-and-opposite reaction on the magnet system.
LOW-VOLTAGE TRANSFORMER TESTlow-voltage a.c.a.c. voltmeterfixed Nₚ, Vₚ, frequencyvary Nₛ; measure Vₛfixed Nₚ · fixed Vₚ · vary Nₛ
Transformer ATP: use prewound insulated coils and an isolated current-limited low-voltage a.c. source.
Induction

Independent: magnet speed at the coil. Dependent: peak magnitude of induced e.m.f. Controls: magnet, coil, path, orientation and sensor settings.

Force

Independent: current. Dependent: balance change or force. Controls: wire length in field, angle, position, field strength and temperature.

Transformer

Independent: secondary turns. Dependent: secondary a.c. voltage. Controls: primary turns/voltage, frequency, core, coil position and meter range.

InvestigationGraphExpected patternBest linked evaluation
peak e.m.f. vs speedmean peak |e.m.f.| against speedincreasing, approximately proportional under fixed geometrymeasure speed at coil, not launch speed
force vs currentmean force against currentstraight line near originbrief current and cooling reduce heating drift
$V_s$ vs $N_s$mean secondary voltage against turnsstraight line near originmonitor $V_p$ to detect source drift
  1. Draw an apparatus that could produce both variables.
  2. Name independent, dependent and at least five controls.
  3. Use five or more settings over a sensible range.
  4. Repeat each setting, identify anomalies and calculate a mean.
  5. Give table headings with units and name both graph axes.
  6. Link each limitation to its physical effect and a specific improvement.
ATP chainAPPARATUS → VARIABLES → REPEATS → MEAN → GRAPH → LINKED EVALUATION

An improvement earns strength when it directly fixes the stated limitation.

Direction evidence: a centre-zero meter records sign; a plotting compass records direction; iron filings only show field pattern.
Safe practical: use only teacher-approved isolated, current-limited low-voltage equipment and insulated prewound coils. Never connect student-built apparatus to mains. Switch off before repositioning leads or coils; stop if conductors become warm.
Quick Check · Why repeat a reference transformer reading?
Returning to the same reference coil reveals source or temperature drift, helping identify whether changes in $V_s$ were really caused by turns.
1
See the trigger before the formula

One picture decoder separates induction, motor effect and transformers

ELECTROMAGNETIC-EFFECTS DECODERFIELD CHANGESinduction /generatorSTEADY CURRENT +FIELDforce / motorA.C. + TWO COILStransformerCHANGE?CURRENT?COILS?
Changing magnetic linkage gives induction; current in a magnetic field gives force; alternating current linking two coils gives transformer action.
SNGtowards coilmeter: deflects
Induction question: ask whether the magnetic field linking the coil is changing.
CURRENT-CARRYING WIRE IN A FIELDNSmagnetic fieldcurrent?force is perpendicular to fieldand current
Motor-effect question: label field and conventional current, then find the perpendicular force.
TRANSFORMER CAUSAL CHAINa.c. in primarychanging currentsoft-iron corechanging fieldsecondary linkedchanging field linkageoutputinduced a.c.e.m.f.needs a changing field
Transformer question: build the complete causal chain from alternating current to induced secondary e.m.f.

Examiner habit: do not start with a hand rule or equation. First identify the physical trigger. “A magnet is present” is not enough for induction; “a wire carries current” is not enough for a force unless the current has a component across the field.

Induction

A conductor cuts field lines or the magnetic field linking a circuit changes.

Motor effect

A current-carrying conductor lies in an external magnetic field.

Transformer

A changing current in one coil makes a changing linked field in another.

Choose a trigger to reveal its evidence chain.
Master mnemonicCHANGE · CURRENT · COILS

Change → induction. Current across a field → force. Two linked coils with a.c. → transformer.

Three traps: a stationary magnet does not continuously induce; a wire parallel to the field has zero magnetic force; a transformer needs a changing primary current.
Quick Check · Magnet and coil move together with fixed separation. Induced e.m.f.?
No continuing e.m.f. Their motion relative to the room is irrelevant: the magnetic field linking the coil is unchanged.
14
One-page examiner logic

Master Electromagnetic Effects by tracking change, directions, components and ratios

ELECTROMAGNETIC-EFFECTS DECODERFIELD CHANGESinduction /generatorSTEADY CURRENT +FIELDforce / motorA.C. + TWO COILStransformerCHANGE?CURRENT?COILS?
Stage 1: identify induction, motor effect or transformer action.
MOTOR DIRECTION MAPFIELD BCURRENT / MOTION?FORCE / CURRENTthe three directions are mutuallyperpendicular
Stage 2: label the two given perpendicular directions before finding the third.
GENERATOR E.M.F. AGAINST TIMEte.m.f.zeropeakzerotroughzero
Stage 3: connect generator coil position with zero, peak, trough and reversal.
FINAL EQUATIONSVₚ / Vₛ = Nₚ / NₛIₚVₚ = IₛVₛ · loss = I²Rideal power only when stated
Stage 4: choose the correct ratio, then sense-check the direction of change.
HIGH-VOLTAGE TRANSMISSIONgeneratorstep-uptransmissioncablesstep-down +usershigh Vlow Ilow I²R heating loss
Stage 5: finish the transmission explanation with lower current and much lower heating loss.

1 · Track change

Induction needs changing linkage. The induced effect opposes the change.

2 · Track direction

Decode N→S, conventional current, motion and dot/cross before using a rule.

3 · Track components

Slip rings maintain generator contact; split ring reverses motor-coil current.

4 · Track ratios

Voltage follows turns; ideal current changes oppositely; cable loss follows $I^2$.

INDUCTION: changing linkage   |   MOTOR: current across field → force   |   TRANSFORMER: $V_p/V_s=N_p/N_s$   |   GRID: $P_{loss}=I^2R$
Final chainCHANGE · OPPOSE · LABEL · TURN · LINK · RATIO · SQUARE

That sequence covers the entire topic from magnet-coil observations to grid efficiency.

Final check · Transformer raises voltage ×4; grid voltage then rises ×5. Ideal current and cable-loss factors?
Ideal transformer current becomes one quarter. At fixed transmitted power, the fivefold grid-voltage rise makes cable current one fifth and cable loss one twenty-fifth.
Interactive mastery: 0 / 9 explored

Explore all nine checkpoints, then move to the independent Practice and Exam Arena banks.